Examples and performances
JINR (Russia)
Super Heavy Element factory
Gas Filled Separator
Christie NHS (UK)
Protontherapy Center
RBA Research beamline
On-site installation and dosimetry
JINR-Acculinna2 (Russia)
Heavy ions beamline
(Xe34+, Kr22+, Fe18+, Ar12+, …)• Length 70 meters
• 4 Dipoles
• 21 Quadrupoles
• 5 Sextupoles
• 3 Octupoles
• 6 Correctors
• All magnets power supplies
• All vacuum chambers and diagnostics
• Vacuum pumping and measuring system
• Vacuum pressure 1.10-6 mbars
Mass Separator
• 3 quadrupoles
• Magnets power supplies
• Vacuum pressure differential 1.10-6 mbar – 2 mbar and Command and Control System
• Beam stopper
ELI
Energy Selection System for ELI
• 4 Dipoles
• 2 Quadrupoles
• 2 Correctors
• Magnets power supplies
• Hall probes
• Vacuum chambers
• All support stands and positioning systems
• Motorized slits
Institute for Plasma Research (India)
300kV High voltage platform & Beamline for High Intensity Proton beam.
- 300 kV HV platform structure with insulators
- one 90° degree bending magnet
- 8 quadrupoles with steering coils
- vacuum pumping and mesuring system
- Beam diagnostic devices
- Control & command software
IOPB
(Institute of Physics of Bhubaneswar – India)
200kV High voltage platform for multi ion ICR source.
- 200 kV HV platform structure with insulators
- 200 kV HV power supply
- 200 kV insulation transformer
Working from a functional specification to purchase a complete beamline is the warranty for :
• Optimizing the complete system and reduce investments and operation costs
• Having a single representative and avoid interface issues
• Handling the global performance
• Reducing your internal expenses in term of specification, detailed design, purchase and technical acceptance of the system
Design capabilities
Beam optics calculation
Vacuum system calculation
For the definition of the pumping system, we are offering our experience, expertise and collaboration with our suppliers, main actors of the market
• Outgasing rate definition according to material and surface finishing
• Conductance calculation
• Primary vacuum pumping down simulations
• Secondary vacuum pumping down simulations
• Vacuum pressure profile along a beamline
Beam diagnostics definition
Sigmaphi, through collaborations and partnerships propose the appropriate beam diagnostics and instrumentation. (Beam position monitor, Beam profile monitor, Beam current monitor, Beam emittance scanner, Slits, Collimators …)
Command and Control systems
We specify and define the command and control systems. We build the complete system and collaborate with reputed experts when necessary.
Pre-assembly and factory tests
Example of manufacturing and complete assembly of a beamline in factory.
On-site installation and commissioning
Pre-assembly and factory tests
On-site installation, tests and commissioning.